3
|
Petrol stations and refineries |
1529 DOWACOAT Uni-Primer Typ 7000
DOWACOAT Uni-Primer Typ 7000 is an adhesion promoter and is primarily used in combination with the DOWACOAT systems on metallic substrates. It is also suitable for activating old coatings. The rapid drying enables rational system processing.
1529 Technical Data Sheet EN
1529 Safety Data Sheet EN
1530 Safety Data Sheet EN
Other languages
1529 Technisches Merkblatt DE
1529 Fiche technique FR
1529 Scheda tecnica IT
1529 Ficha técnica ES
1529 Ficha técnica PT
1529 Sicherheitsdatenblatt CHD
1530 Sicherheitsdatenblatt CHD
1529 Fiche de données de sécurité CHF
1530 Fiche de données de sécurité CHF
1529 Scheda di dati di sicurezza CHI
1530 Scheda di dati di sicurezza CHI
1529 Ficha de datos de seguridad ES
1530 Ficha de datos de seguridad ES
1529 Ficha de dados de segurança PT
1530 Ficha de dados de segurança PT
Article-No | Designation | Content | SU | Packaging unit | Piece | |||
---|---|---|---|---|---|---|---|---|
1529.8 | reddish | 8 kg | (1) | bucket |
|
A | ||
1529.4 | reddish | 4 kg | (1) | bucket |
|
A | ||
1530.2 | Component B, hardener Typ 9500 | 2 kg | (1) | canister |
|
A | ||
1530.1 | Component B, hardener Typ 9500 | 1 kg | (1) | canister |
|
A |
Danger and safety instructions: 1530 Component B, hardener Typ 9500
Flammable
|
Harmful
|
Health Hazard
|
Danger
H225: | Highly flammable liquid and vapour. |
H315: | Causes skin irritation. |
H317: | May cause an allergic skin reaction. |
H319: | Causes serious eye irritation. |
H334: | May cause allergy or asthma symptoms or breathing difficulties if inhaled. |
H335: | May cause respiratory irritation. |
H336: | May cause drowsiness or dizziness. |
H351: | Suspected of causing cancer. |
H373: | May cause damage to organs. |
EUH204: | Contains isocyanates. May produce an allergic reaction. |
P201: | Obtain special instructions before use. |
P210: | Keep away from heat / sparks / open flames / hot surfaces. – No smoking. |
P240: | Ground / bond container and receiving equipment. |
P241: | Use explosion-proof electrical equipment. |
P242: | Use only non-sparking tools. |
P243: | Take precautionary measures against static discharge. |
P260: | Do not breathe dust / fume / gas / mist / vapours / spray. |
P261: | Avoid breathing dust / fume / gas / mist / vapours / spray. |
P264: | Wash hands thoroughly after handling. |
P271: | Use only outdoors or in a well-ventilated area. |
P272: | Contaminated work clothing should not be allowed out of the workplace. |
P280: | Wear protective gloves / protective clothing / eye protection / face protection. |
P284: | Wear respiratory protection. |
P312: | Call a POISON CENTER or doctor / physician if you feel unwell. |
P362+P364: | Take off contaminated clothing and wash before reuse. |
P302+P352: | IF ON SKIN: Wash with plenty of soap and water. |
P303+P361+P353: | IF ON SKIN (or hair): Remove / Take off immediately all contaminated clothing. Rinse skin with water / shower. |
P304+P340: | IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. |
P305+P351+P338: | IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. |
P308+P313: | IF exposed or concerned: Get medical advice / attention. |
P333+P313: | If skin irritation or rash occurs: Get medical advice / attention. |
P337+P313: | If eye irritation persists: Get medical advice / attention. |
P342+P311: | If experiencing respiratory symptoms: Call a POISON CENTER or doctor / physician. |
P370+P378: | In case of fire: Use … for extinction. |
P405: | Store locked up. |
P403+P233: | Store in a well-ventilated place. Keep container tightly closed. |
P403+P235: | Store in a well-ventilated place. Keep cool. |
P501: | Dispose of contents / container in industrial incinerator |
Danger and safety instructions: 1529 DOWACOAT Uni-Primer Typ 7000
Flammable
|
Harmful
|
Environmental Hazard
|
Danger
H225: | Highly flammable liquid and vapour. |
H319: | Causes serious eye irritation. |
H336: | May cause drowsiness or dizziness. |
H411: | Toxic to aquatic life with long lasting effects. |
EUH066: | Repeated exposure may cause skin dryness or cracking. |
EUH208: | May produce an allergic reaction. |
P210: | Keep away from heat / sparks / open flames / hot surfaces. – No smoking. |
P240: | Ground / bond container and receiving equipment. |
P241: | Use explosion-proof electrical equipment. |
P242: | Use only non-sparking tools. |
P243: | Take precautionary measures against static discharge. |
P261: | Avoid breathing dust / fume / gas / mist / vapours / spray. |
P264: | Wash hands thoroughly after handling. |
P271: | Use only outdoors or in a well-ventilated area. |
P273: | Avoid release to the environment. |
P280: | Wear protective gloves / protective clothing / eye protection / face protection. |
P312: | Call a POISON CENTER or doctor / physician if you feel unwell. |
P391: | Collect spillage. |
P303+P361+P353: | IF ON SKIN (or hair): Remove / Take off immediately all contaminated clothing. Rinse skin with water / shower. |
P304+P340: | IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. |
P305+P351+P338: | IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. |
P337+P313: | If eye irritation persists: Get medical advice / attention. |
P370+P378: | In case of fire: Use … for extinction. |
P405: | Store locked up. |
P403+P233: | Store in a well-ventilated place. Keep container tightly closed. |
P403+P235: | Store in a well-ventilated place. Keep cool. |
P501: | Dispose of contents / container in industrial incinerator |